RF Cell Plus™ | Thermage and Fractional Microneedle RF Skin Lifting Machine
RF Cell Plus™ successfully combines latest revolutionary Fractional Microneedle RF technologies with Fractional Thermal RF technology in one system to achieve the most optimal treatment result for both epidermis and dermis.
Features
- One System with three functions
- Fractional Microneedle RF function
- eMatrix Fractional RF function
- Cryotherapy hand piece for quick skin recovery
- Dynamic Liner Motor Technology
- Accurate Needle Depth Control : 0.5~3 mm [0.1mm Step]
- Precise RF pulse time control by 0.1 sec
- Adopts Non-Insulation Gold coated micro needles
- Fractional Multipolar RF with 25 needles, 49 needles and 81 needles
- Noticeable result after only one treatment
Technologies
5 in 1 integrated advanced technologies
- Micro Needling Therapy
- Fractional RF Thermal Energy
- Fractional Microneedle RF
- Fractional Multipolar RF
- Dynamic Linear Motor Technology
- Accurate Control Technology
- Non-insulation Plating Technology
- Cryotherapy
- Video Introduction
Micro Needling Therapy (wound-healing therapy)
Micro needling delivery provides unparalleled collagen induction therapy via fractional delivery of needles into the epidermis and dermis. These micro injuries to the skin encourage and harness the power of the body’s innate ability to re-grow and repair the skin through the physiology of collagen induction. It is a Non-surgical skin rejuvenation treatment which is widely used for skin rejuvenation, enhancement of skin elasticity, wrinkle reduction, acne scar reduction, and stretch mark reduction, stimulation of hair growth, whitening and administration of active ingredients.
Fractional RF Thermal Energy
Collagen is regenerated by delivering 55~65℃ of RF heat energy on fibrous coat. Fiber blast and collagen fiber are stimulated through delivered RF energy which result in improvement of wrinkle, elasticity strengthen and care for troubled skin.
Innovative Fractional Microneedle RF technology
Precisely controlled Bi-polar RF energy will be delivered into a certain depth of dermis through a minimally invasive gold-coated mirconeedles in order to induce dermal coagulation.
Microneedle penetration length can be adjusted from 0.5 to 3mm depth selectively considering the target areas depending on symptoms.
Fractional Multipolar RF Technology
Fractional multipolar radio frequency technology places the heat energy effectively into the upper dermis where it can produce a significant increase in both collagen and elastin with minimal epidermal disruption.
The unique Sublative ergonomic applicator delivers radio frequency energy via the matrix of 64 electrodes. This fractional delivery of RF energy causes micro-epidermal ablative injuries with wider-spread dermal coagulation. This initiates a strong wound-healing response in the dermal matrix while also minimizing the damage to the epidermis. Less affected tissue surrounding the matrix points may be stimulated by heat, which helps accelerate the healing process, leading to a smoother, rejuvenated appearance of the skin.
Dynamic Linear Motor Technology
Different to existing Solenoid Type, the needle controlled by Dynamic Linear Motor Technology inserts to the skin softly and smoothly to greatly reduce risk of bleeding and cause much less pain than other method. The Dynamic Linear Motor Technology ensure RF energy only released after needle is completely inserted into treatment zone to avoid potential risk of electricity shock. Furthermore, it also enable each needle penetration with the same strength and length for maximum treatment result.
Accurate Needle Depth Control : 0.5~3 mm [0.1mm Step]
Operates epidermis layer and dermis layer by controlling the needle depth in unit of 0.1mm. It is cost effective and more convenient for different treatment conditions. Adjustable needle depth control allows for customized and reproducible treatments of delicate areas.
Precise RF pulse time control by 0.1 sec
RF Cell plus™ allows operators to precisely control each RF pulse energy by 0.1 second to maximum result.
Non-Insulation Plating ensure heating from epidermis to deep dermis
Different from insulated plating. The unique non-insulated micro electrodes enable continuous heating from Epidermis Layer and Dermis Layer for optimal result with minimal pain and downtime.
Cryotherapy
The cold therapy hand piece adopts water cooling with semiconductor cooling. It can effectively keep the temperature between -5℃~5℃ in 5 minutes. It is a perfect combination for RF treatment, because it quickly reduce the temperature of epidermis , accelerate skin recovery and greatly reduce downtime.
Working Principle of Fractional Micro needle RF Machine——RF Cell Plus
Design
Genius Outward and Scientific Inner Design
RF Cell Plus adopts high quality ABS material for machine body case. It makes the body shape professional, what’s more, you will never worry about the case damaged during the long overseas transportation.
Intelligent module design guarantee easy repair and maintenance.
Foot Switch and Emergency Button for Safety Operation
User friendly software
Different to existing Solenoid Type, the needle controlled by Dynamic Liner Motor Technology inserts to the skin softly and smoothly to greatly reduce risk of bleeding and cause much less pain than other method. The Dynamic Liner Motor Technology ensure RF energy only released after needle is completely inserted into treatment zone to avoid potential risk of electricity shock.
Gold coated needle is more durable and has high Biocompatibility. Patient with metal allergy could also use it without concerning Contact Dermatitis.
25 micro needle as electrodes is able to reduce pain and allow easier dedicated depth control. It is more adaptive for small area treatment such as eye around areas and lips
The needle structure is easy to penetrate the skin with minimum resistance, which greatly reduce pain and downtime
Compare
Advantages by Comparison
Difference between Microneedle RF and Laser
Advantage of Radio Frequency
- No matter what skin type is suitable for RF
- Easy penetration up to target area
- Less risk of side effects
Disadvantage of Laser
- Selective laser absorption
- Penetrations vary depend on absorption rate for water, hemoglobin, melanin etc.
Difference between RF intensity and treatment time
Short time, High power
- Thick and Wide Old Scar
- High Expectaion
- Burning, Fibrosis
- Painful, Downtown
Middle Level
- Wrinkle & Tightening
- Acne Scar
- Facial & Neck Lifting
Long time, Low power
- Pore, Active Acne
- Skin Rejuvenation
- No pain & Downtown (but lower than expectaion)
Fractional Micro Needle RF: Minimal invasive 25 gold coated electrodes
Fractional Multipolar RF (Matrix RF): Non-invasive 64 electrodes
Fractional Micro Needle RF: Multipolar(Bipolar) & Monopolar
Fractional Multipolar RF (Matrix RF): Multipolar(Bipolar)
Fractional Micro Needle RF: Adjustable with Needle length from 0.5~3mm
Fractional Multipolar RF (Matrix RF): Unadjustable
Fractional Micro Needle RF: Target area from epidermis to deep dermis layers.
Fractional Multipolar RF (Matrix RF): Superfacial layers
Application
Facial:
- Non-surgical Face Lifting
- Wrinkle Reduction
- Skin Tightening
- Skin Rejuvenation( Whitening)
- Pore Reduction
- Acne Scars
- Skin with flushing and enlarged blood vessel.
- Skin texture improvement
Body:
- Scars
- Stretch Marks
- Keratosis Pilaris
- Hyperhidrosis
Specification
Fractional Micro-needle RF | |
---|---|
RF type | Bipolar |
RF frequency | 5Mhz |
RF pins | Gold coated 25 pins, 49pins, and 81pins |
Output Power | Max 20W |
Spot Size | 12*12mm, 20*20mm, 41*41mm |
Repetition rate | 1.0, 2.0, 3.0 & manual |
Needle depth | 0.5~3.0mm (0.1step) |
Needle thickness | 0.3mm |
RF duration | 10-300ms |
Fractional Multi-polar RF (Matrix RF) | |
RF type | Multipolar |
RF frequency | 5Mhz |
RF pins | 64 pins |
Output Power | Max 50W |
Spot Size | 5*5mm for eye 15*15mm for face |
RF duration | 10-300ms |
Cryotherapy hand piece | |
Cooling temperature: | Cold: -2℃~20℃ Heat: 37℃~45℃ |
System | |
Screen | 10.4inch Color Touch Screen |
Protection System | Foot switch, Emergency switch |
Cooling system | Air cooling+Water cooling |
Power supply | AC220V±10%, 50Hz; AC110V±10%, 60Hz |
Total output power | 250VA |
Net weight | 28KG |
Dimensions | 28cm x 50cm x 110cm |
Result
Skin Whiten
Skin Rejuvenation
Acne & Acne Scar
Stretch Marks
Skin Lifting
Large Pores
Product FAQ
Why does our skin lose elasticity and start to sag?
Even with a healthy lifestyle and minimal sun exposure, our skin gradually loses its firm, youthful look. Aging, cumulative sun exposure, multiple pregnancies, and weight fluctuation are all factors which affect the strength and elasticity of the collagen fibers in our skin. This, in turn, causes the wrinkles and sagging skin.
Can sagging skin be corrected non-surgically?
Skin laxity can be improved by employing novel non-invasive energy-based technologies. Micro needle RF is possible to tighten loose skin and promote production of new, healthier collagen
What is the RF Cell Plus technology?
The RF Cell Plus technology is an advanced fractional microneedle RF technology which enables fractional skin resurfacing and treatment of wrinkles and scars. RF Cell Plus energy is delivered to the skin in a fractional manner via an array of micro-electrode pins. RF Cell Plus creates small zones of treated tissue in the epidermal areas which are in direct contact with the micro electrodes and delivers deep heat into the dermis. The fractional manner leaves intact zones in between the targeted areas which serve as a pool of cells reservoir that promote a faster more effective healing process. In the epidermis, the affected spots result in small scabs that shed off the skin after a few days, leading to an improved skin tone and texture. In the dermis, treatment induces remodeling of dermal collagen (neocollagenesis) and of other dermal components. RF Cell Plus treatment enables safe, tolerable and effective skin rejuvenation.
What should I expect during treatment?
40° C (hot shower temperature). Your skin temperature will be constantly monitored. Depending on the size of the treatment area, treatment may take between 30-45 minutes. The treatment is relaxing, pain free and carries no side effects.
How long does a RF Cell Plus treatment take?
The topical anesthetic cream requires 20 to 30 minutes to take effect prior to treatment, and then the treatment takes 20 to 30 minutes, including aftercare. So, each session requires approximately 1 hour.
How many treatments are required to see the results?
According to your treatment program, your physician will offer a series of treatments, up to six, in intervals of one to two weeks. You should start to see improvement in your skin following the second treatment and additional improvement will gradually appear as the treatment course progresses.
As new healthier collagen is formed, tighter, more natural looking and firmer skin will be produced. The gradual improvement in your skin will continue even after completion of the treatment series.
Is the RF Cell Plus treatment painful?
With the correct application of topical anesthesia, it is virtually painless. It is also possible to treat to a 1mm depth without topical anesthesia.
How long is recovery after RF Cell Plus treatment?
You may experience transient erythema on the treated areas for 3-4 hours initially. Occasionally, a fine scab will be formed on the skin – do not be concerned, this is an expected part of the healing process.
What is the recommended RF Cell Plus treatment regimen?
The typical interval between sessions is once every 3 weeks. Most patients see excellent results following 4-5 treatments. This may vary according to your skin condition and your physician will be better able to assess and advise you of this.
Are there any precautions after RF Cell Plus treatment?
Avoid cleansing until after the erythema has resolved itself. Cleanse your skin with cool water and dab or pat lightly with a towel. Avoid hot water. Sunscreen should be applied every day to protect your skin and you should limit sun exposure during the treatment course.
What side effects can I expect?
After the treatment, the skin may look sunburned, with large areas of redness. This redness usually fades within a few days, and can be covered with makeup.