SlimOne X8™ | Powerful Multi-functional Non-invaisve Body Sculpting Platform
SlimOne X8™ is one of the world’s most powerful multi-applicatons non-surgcial body sculpting machine on the market combining 8 advanced technologies in one single platform. It provides complete and advanced facial and body care treatment such as fat reduction, body shaping, cellulite reduction, skin tightening, wrinkle reduction, facial rejuvenation etc.
Features
- Integrating 8 latest body contouring technologies in ONE platform.
- High efficacy and cost-efficient for cellulite reduction, body contouring and skin tightening.
- 4th generation Cryolipolysis technology to freeze fat off
- 4th generation non-thermal Ultrasonic cavitation to reduce localized fat.
- Dual wavelength low level laser for weight loss.
- Innovative Body Vacuum RF applicator for lymphatic drainage and skin lifting.
- Tripolar RF for face lifting and skin rejuvenation.
- Two Cryolipolysis applicator works simultaneously to maximum treatment efficiency.
- High power Low level laser imported from Mitsubishi, Japan.
- Low level laser works independently allowing applying two treatments at the same time.
- Cryolipolysis real temperature 5℃ to -16℃
- Imported components ensure reliable and robust performance.
- Completely Painless, comfortable and no downtime.
- Consistent , Measurable and reproducible result
Technologies
Advanced body sculpting technologies
- 4th Generation Cryolipolysis
- 4th generation ultrasonic cavitation
- Dual wavelength low level laser
- Innovative Body RF applicator
- Bipolar RF + Tripolar RF
- Product video
- Treatment video
4th Generation Cryolipolysis for fat freezing
The treatment principle of Cryolipolysis is based on the scientific fact that triglyceride will be solidified under 4°C, through the non-invasive headpiece to transmit the cryo effect to the localized fat reducing part, the cooled fat cells begin a process called “apoptosis” and begin to shrink. These damaged fat cells are slowly digested over several months by our bodies and removed through the liver. This technology is highly effective and is producing consistent results for local areas of fat like the love-handles or ‘man-boobs’, though larger areas of fat may require more invasive treatments. There is no damage to other tissue types. According to clinical researches, cryolipolysis can reduce the thickness of fat layer by 25% just within 2-4 months.
4th generation Cryolipolysis technology combines Vacuum Suction, Blue Photon and Cryo functions in one applicator offering selective, precise and effective treatment. Fatty tissues are held into the chamber for selective cryo treatment without harming nerves or blood vessels. Beside, the sealed chamber provides more efficiency cooling effect and block blood supply to prevent frost bite.
4th Generation Non-thermal Ultrasonic cavitation energy for effective fat reduction
Cavitation slimming technology is non-thermal and non-invasive technology based on ultrasonic waves which generates empty micro bubbles in the liquid situated in the interior of the adipose tissue. Its repeated action causes the accumulation of these micro bubbles, which causes the fat cells to implode and collapse. The result is the destruction of the adipose cells transforming the fat nodules into liquid substances that the body removes in a natural way through the lymphatic system. The mechanism is cavitational mechanical destruction (empty micro bubbles ) of adipose tissue rather than thermal energy. It only generates little warm which is caused by ultrasound wave vibration.
4th generation Non-thermal Ultrasonic cavitation delivers low noise and low heat cavitation technology for the optimal fat reduction treatment.
Dual Wavelength Low Level Laser:
650nm: non-thermal laser for fat removal
980nm: thermal energy for liquefaction of fat and lymphatic drainage
Low Level Laser 650nm emits low level of laser energy which stimulates the fat cell membranes and change their permeability. The fat cells lose their round shape, and intracellular fat is released. Thus, the fatty triglycerides flow out of the disrupted cell membranes and into the interstitial space, from which they gradually pass through the body’s natural metabolic functions with no harmful physiological effects. The fatty triglycerides is to be used as an energy source for the body. This whole process does not alter neighboring structures such as the skin, blood vessels, and peripheral nerves. Different from other fat reduction technology, it is not merely the liquefaction of fat but rather the instant breakdown of fat cells, which is also known as lipolysis. It only generate very mild warm during treatment. It is non-thermal technology for fat removal. It is completely non-invasive, no side effect and no downtime.
980nm wavelength laser energy penetrates well into tissue and is preferentially absorbed by lipids causing fat liquefaction. The temperature inside the adipocytes is slightly elevated. Combines with 650nm laser, it achieve more effective fat reduction.
Innovative Body RF applicator:: Vacuum + LED Photon + Multi-polar RF
- Multi-polar RF
Multipoalr RF thermal heating promotes an increase in blood circulation, lymphatic drainage, cellular metabolism and collagen depositing. Furthermore, it stimulates fibroblast activity and remodels the extracellular matrix. - Vacuum massage:
Vacuum massage performeffective lymphatic draining to increase the elasticity and flexibility of the skin and gives you a great help in eliminating the toxins through the lymphatic system. - Red led photon:
Specific wavelengths of red light (650nm) are proven to boost overall cellular energy, increasing our body’s natural production of collagen and elastin and increasing microcirculation.
The red light penetrating 8-10mm is suitable for any type of skin; it can reach derma to stimulate fiber cells. Heating can improve blood circulation and collagen albumen hyperplasia to reduce wrinkles and make skin more elastic and smooth.
The combined three technologies provides significant improvements in overall cellulite appearance and skin condition with a long-lasting result。
Advanced Facial Applicator:
Bipolar RF+ Photon LED; Tripolar RF+ Photon LED
Bi polar RF and Tripolar RF technology offer new scientific development in treatment of body sculpting, anti-aging and skin tightening. High radio frequency frequency wave permeates epidermis and take effect on the collagen-rich dermal tissue directly which makes water molecules in the skin move to and fro wildly. The move produces controllable heat and results in contraction of collagen and generation of new collagen and dermal remodeling . As a result, the skin looks tighter, and wrinkles are reduced gradually.
SlimOne introduction video
SlimOne treatment video
Design
High-end built quality and sate-of-the art design
- Advanced Cryolipolysis applicator
- Advanced Low Level Laser
- Integrated ultrasonic transducers
- Efficient cooling system
- Superior components
- State-of-the-art design
- Intuitive and professional software
- Safety power supply system
- Product operation video
- Real Cryolipolysis
SlimOne adopts same coolsculpting technology as Zeltiq. It combines Vacuum Suction, PDT and Cryo functions in one applicator offering selective, precise and effective treatment.
- Cryo temperature 5℃~ -16℃ continusly adjustable
Operators can adjust the temperature from 5℃~-16℃ continously offering more options for different conditions.
- Blue LED 415nm
Blue LED targets the metabolic product of propioni bacterium bacteria, porphyrins, and produces an oxygen free radical from these porphyrins that kills the bacteria. This anti-bacteria functions helps reduce bacteria counts and inflammation - Two coolsculpting applicators (small and medium size):
– different applicator size for different body areas.
– working at the same time : This design gives you the ability to treat two patients with one machine or treat two body parts to improve efficiency.
– Large applicator for option: 12cm(W)*25cm(L)*8cm(D) (optional) - LCD display:
Monitor temperature, water flow , and negative pressure. - Flexible cooling pad:
Two cooling pad can be adjusted for a small angle to provide comfortable treatment. - High quality medical grade soft silicon cover
– High hygiene.
– anti-aging and durable.
– much conformable for treatment than hard plastic materials.
Advanced Low Level Laser:
High power Low Level Lase imported from Mitsubishi, Japan
- Real 100-200mw (pulsed) power of each laser lamp
- Independent control board for each pad for easy maintenance.
- Big pad comes with fan cooling for heavy duty performance.
- Dual wavelength 650nm& 980nm providing more efficient result.
Total: 104 pcs of laser lamp; Total out power: Max 10W - Independent low level laser control system:
This give you the ability to control the low level laser pad Independently without affecting other functions. In other words, you can apply cavitation or Cryolipolysis treatment on one patient while doing lipolaser treatment on another patients. It is cost-efficient and cost-saving.
Integrated ultrasonic transducer:
– output highly stable and powerful cavitation energy
– low heat – low noise
– durable and longer service life.
Efficient cooling system: enable continuous working over 20 hours
- Powerful air cooling fan:
– 6 pcs of powerful fan built inside.
– High quality fan made by SUNON: low noise and powerful cooling.
- 9L large water tank:
integrated stainless steel water tank: durable and reliable. - Peltier:
Two large peltiers built inside both side of the applicators - High power diaphragm pump:
Diaphragm pump performs better than magnetic pump for water cycling. It generate low noise and low heat.
- High quality rust-proof radiator :
Large rust-proof radiator for efficient heat radiating.
- High quality ABS material machine case
Durable and luxury appearance. It is much better than cheap PVC materials.
- Two powerful air compressor
– Low noise, strong power
– Durable and reliable.
– Max power: ≥150KPa
- Imported Germany hand piece cable
Durable, anti-color-fading and high quality. Comfortable to operation. - Aluminium hand piece holder
- High quality air tube
– Longer service life than other soft material.
– Stronger enough for Maximum air pumping.
- Germany Proportional valve.
- Japan Electromagnetic valve
- Quick-plug-in design:
Installing hand piece is never been so easy. It only takes 10 seconds to finish the hand piece installation by simply pluging into the sockets. The integrated connector is easy to install and maintenance. - Ergonomic designed hand pieces
Easy to hold and convenient to operate - Modular design:
SlimOne adopts its modular design. Every components of the machine is standardized and can be easily changed. - Full access to all the components:
It’s easy to open up the back cover and access all the components enable easy repair and maintenance. - Auto filter system :
Automated filter system protect the machine from sucking in harmful objects such as liquid products and gel during vacuum operation . Those objects are automatically filtered into bottles , which makes cleaning and maintenance easy to do. - Stainless steel structure:
2mm thick steel: durable and safe for oversea shipping.
- Luxury 8 inch touch screen
- Each function can be controlled adjusted independently :
Each applicator integrated multiple functions. Each function can be adjusted and controlled independently. You can turn off or adjust any functions according to the specific situations. It gives operators flexible control of the device providing the optimal treatment experience.
- Various suction options providing the most comfortable and effective treatment experience for different situations.
- Independent control of coolsculpting and lipolaser functions
SlimOne X8™ has two power control system for the maximum protection.
Main power supply+ Emergency power switch
The design protect from any accidental operation or electricity shortage .
SlimOne low level laser demo
Compare
Advantages by Comparison
- Cryolipolysis applicator
- Low Level laser comparison
- Real cavitation VS fake cavitation
- Cooling system comparison
- Hardware compare
- Real energy test video
- Cryo temperature:
– SlimOne achieves real cooling temperature from 5℃ to -16℃. Other machine only reach to -7℃ or -5℃.
– SlimOne provides continuous adjustment of cooling temperature. Other machine only provide two or three levels. - Coolsculpting applicators
– SlimOne provides three different size for optimal treatment: Small, Medium and Large size (optional). Other machines provide only one or two size.
– SlimOne enable two applicators working the same time without compromise of performance. Other machine can only work with one applicator. - LCD display:
SlimOne offers LDC display to easily monitor the working conditions. Other machines don’t have LCD display. - Medical grade soft silicon cover VS hard cheap plastic cover:
– more hygiene
– more comfortable
– longer service life and easy to clean.
- Flexible cooling pad VS fixed cooling pad
The structure of cooling pad allows small angle adjustment to provide more comfortable suction during treatment.
- Mitsubishi, Japan Laser VS China laser
SlimOne uses imported Mitsubishi laser with Maximum 100mW power, Other machines may use China laser with power range from 5mW to 50mW
- Diode Laser lamp VS LED lamp
Some company use cheap LED lamp advertised as laser lamp. LED lamp is not effective for body slimming at all.
- Two wavelength VS one wavelength:
SlimOne offers two wavelength on one lipolaser pad: 650nm and 980nm. It is more effective than single 650nm. - Independent low level laser control system:
The lipolaser function can be controlled independently. You can perform lipolaser treatment while applying another function without any problem. Other machines don’t allow two different functions working the same time. - Diode laser number:
SlimOne has total 104pcs laser lamp: 24 pcs on large pad; 4 pcs on small pad. Total power is 10W. Other machine has only 10 or 5 pcs of laser lamp on large pad. It offers only 80 pcs or 50pcs of laser lamp.
- Lipolaser pad with fan air cooling built inside:
The large pad holds one big fan and five small fan inside to provide efficient air cooling for heavy-duty performance. Other laser pad don’t have any cooling system which shorten the treatment time.
In recent years, ultrasonic cavitation is becoming the most widely used technology for fat reduction treatment in beauty salons. With more and more cavitation machines in the market, we find that there are lots of fake cavitation machines. These machines only use simple ultrasound technology which cannot create cavitational effect and has no result for body slimming. Please be aware when you are shopping for a real effective cavitation machine.
How to tell he real cavitation from simple fake ultrasound device?
Drop water on the ultrasound transducers and observer the water reaction when the ultrasound is working. The real cavitation probe causes water splash rather than water mist.
The water splash is caused by the high pressure generated by exploding of empty micro bubbles. Only real cavitation can cause such effect. Other simple ultrasound cause water vaporization rather than splash, which is based on the theory of resonance of high frequency ultrasound. his effect is normally performed by regular 3MHZ ultrasonic beauty device. Many fake cavitation machines use simple 3MHZ ultrasound to produce a strong mist phenomenon to deceive consumers.
You can see the pictures of true cavitation effect on water here.
- Highly efficient cooling system: achieve desired temperature in 3 to 5 minutes.
SlimOne utilizes four cooling system: Air cooling + Water cooling + Peltier cooling + Heat radiator. Four systems working simultaneously enable desired temperature can be achieved in very short time. - High quality rust-proof heat radiator VS low quality radiator:
- Integrated stainless steel water tank VS cheap PVC plastic tank.
Inner hardware comparison between SlimOne and other machine in the market.
Low Level Laser energy test
Application
- Cellulite reduction
- Body contouring
- Weight loss
- Deep fat blasting
- Skin tightening and lifting
- Face lifting
- Wrinkle and fine lines removal
- Large pore shrinkage
- General reduction of waist, abdomen & buttock
- Promote metabolism and lymphatic drainage
- Collagen stimulation and generation
Specification
SlimOne X8 | |
---|---|
CRYOLIPOLYSIS | 1 applicator for body; 1 applicator for legs and arms |
CRYO applicator size | Small:7cm(W)*13cm(L)*5cm(D)(default); Medium:10cm(W)*20cm(L)*8cm(D)(default); Large:12cm(W)*25cm(L)*8cm(D) (optional) |
Cryo temperature | 5℃~ -16℃ (continusouly adjustable) |
CAVITATION | 1 piece of 40KHz probe |
Cavitation Power | 100W |
Cavitation frequency | 40Khz |
Cavitation applicator size | 7cm(diameter) |
RADIO FREQUENCY | 1 pcs Bipolar RF with Red Photon; 1 pcs Tripolar tips with Red Photon; 1 pcs Vacuum Multi-polar RF tips with Red Photon |
RF probe size | Bipolar: 2.5 cm (diameter); Tripolar: 4.5cm(diameter); Mutipolar: 10cm(diameter) |
Radio Frequency | 5MHz |
RF energy | 50J (Max) |
Low Level Laser | Mitsubishi diode laser |
Laser lamp power | 100mW~200mW (pulsed) |
Laser wavelength | 650nm; 980nm |
Laser number | 4pcs of Large pad: 96pcs 2 pcs of small pad: 8pcs Total: 104pcs |
Laser pad siz | Big pad: 15*8cm; Small pad: 8.5*5cm |
Laser pad cooling | Air cooling |
Blue Led Photon | 415nm |
Red LED Photon | 650nm |
Vacuum suction model: | Pulsed/ Continuous. |
Negative Pressure | 0-100Kpa |
Power Supply | AC220V±10%, 50Hz; AC110V±10%, 60Hz |
Display | 8 inch LCD Touch Screen |
Hand piece cable | 180 cm |
Water tank | 9L |
Cooling System | Air+Water+Peltier+Radiator |
Machine Size | 110cm*50*49cm |
Package Size | 132*65*60cm |
Gross Weight | 65Kg |
OEM Service | MOQ over 1 pcs |
Result
fat removal
body contouring
wrinkle reduction
Product FAQ
What's Cryolipolysis technology ?
Cryolipolysis, also called CoolSculpting or coolshaping is a new, FDA approved, fat reduction alternative to liposuction for people with a small amount of fat that resists diet and exercise. CoolSculpting is a totally non¬invasive, in office procedure that uses Cryolyposis to target, freeze and permanently eradicate fat cells.
How does CoolSculpting work?
This fat reduction technique works through a method called Cryolipolysis for the selective targeting and freezing of the fat cells in the treatment area. The procedure is performed using a small cooling device that is placed on the area to be treated for approximately 1-2 hours. After feeling some tightening and pressure on the treatment area initially, the area then becomes numb and nearly unnoticeable to the patient. Patients may work on their laptop, read, listen to music or even nap while the procedure takes place. The CoolSculpting system targets and freezes the fat cells in the area being treated, thereby, destroying the fat cells which are then absorbed and eliminated naturally through the body. There is no downtime and patients may return to their daily routine immediately, including work or their normal fitness routine.
Is cavitation fat reduction treatment safe?
Yes, cavitation treatments is non-invasive and non-surgical. Cavitation technology has been studied and used for over 30 years for many biomedical purposes. The technology has been FDA approved in USA. The treatment is painless and has no downtime.
Who is candidate for the SlimOne procedure?
SlimOne treatment is a very suitable for people with fat. It is not a suitable treatment for those who have less than 1cm depth of fat in the area to be treated. In addition, it is not suitable for those who are pregnant, have a blood clotting disorder, a history of cancer and related conditions or cardiovascular devices fitted eg. pacemaker.
Does cavitation/RF treatment hurt?
The level of discomfort experienced will depend on the area that is being treated. The feeling has been described as a prickling, warm feeling with some squares treated being more uncomfortable than others. Immediately after the treatment the area will look red and may feel tender.
Will my skin sag after the fat has gone?
As only a small area of fat is being treated, the amount of fat being destroyed and liquefied will not be enough to create a sagging of the skin. There is also some evidence to suggest that the heat of the treatment itself does cause an element of skin tightening.
What happens to the fat in the treated area?
The destroyed fat cells at the treated area are reabsorbed by the body over the following 12 weeks. The dead fatty cells are naturally eliminated from the body, permanently removing the damaged fat cells from the body, leaving a slimmer waistline.
How quickly will I see results?
It is not unusual for the results to take up to 12 weeks to be fully seen and the treated area will likely go through various changes in texture and feel during that time. The area can often feel ‘doughy’ or ‘jelly like’ and many patients initially experience an increase in urination. All of these changes are quite normal and will eventually settle down.
How long do the results last?
As long as additional weight is not gained, the fat cells will not return to the treated area. The treatment will not prevent new fat cells from developing and the patient is encouraged to continue with a balance of healthy eating and exercise to maintain the results.
Why do patients hear "tinnitus sound" during ultracvaitation treatment?
Although our cavitation technology has greatly reduced the tinnitus sound level, it’s very hard to completely reduce it because this is normal for all ultrasound with such low frequency. If patients find the tinnitus sound uncomfortable. You can improve the situation with the following tips:
- Don’t touch the probe with water. If there is water on the probe during treatment, it will cause loud noise and also heat up very quickly.
- Use pure ultrasound gel or high quality slimming gel.
- Don’t move the probe too quickly. Move it slowly. Place the probe firmly on the treated area. Avoid probe rubbing on the skin frequently.
- Listening to music with headphone will ease the feeling .
Can we use cavitation for facial treatment ?
No, you cannot. We strongly against using cavitation on face and neck area. Cavitation energy can reach very deep. Face or neck has very thin skin and very little fat tissues. The energy may reach organ /bones and cause damage on those areas. Some other irresponsible companies may advertise their cavitation can treat face and neck. The fact is that their technology is not actual cavitation but only simple 1Mhz or 3Mhz ultrasound. Such ultrasound don’t have any effective result for tightening or fat reduction. If you want to perform facial treatment, please consider RF technology as is perfectly safe for face.
What's the best protocols for body slimming treatment?
We recommend doing the treatment following below steps:
1, Massage the treatment area for 10 minutes:
you can do it by hand. Or you can do it with the vacuum RF hand piece which is clearly better than hand massage. It helps to relax the treatment area and increase lymphatic drainage.
2, Low level laser for 30 minutes.
If you have the lipolaser machine, you can use it for 30 minutes. it helps to release fatty triglycerides out of the disrupted cell membranes.
3, Cavitation for 15~30 minutes
Use the cavitation on the hips for 30 minutes. Please make sure the cavitation energy is good enough. The cavitation break down fatty cells to pieces.
4, Cryolipolysis for 45~60 minutes
Cryolipolysis is a Revolutionary Non-invasive Natural way to lose stubborn fat. The energy freeze adipose tissue to death without harming other areas.
5, Vacuum RF treatment for 10 to 20 minutes.
Apply the vacuum RF for 20 to 30 minutes. It massages the areas and helps for lymphatic drainage, skin tightening and body slimming. The Vacuum RF treatment is very effective and essential to get the dead adipose tissue out of the body system.
Combing those treatment, it takes about Maximum 2 hours to compete. Obvious result can be seen after one treatment only. The combines energy can shorter the treatment interval session to about 1 to 2 weeks rather than 3 or 2 days per session.
How many centimeters can I reduce from my circumference?
In clinical studies, patients report an average reduction of 1 – 3 centimeters for 1 treatment. Still, results can be highly individualized varying from subtle to dramatic, depending upon the physical state of the patient prior to treatment and the patient’s adherence to a healthy lifestyle. Patients can lost 0.5 inch to 3 inches post treatment, however it is not unreasonable to exceed even these results.
Are there any side effects?
Short term effects can include mild bruising or redness. There is also a risk for mild, superficial burns in a very small percentage of the population, but these are exceedingly rare. If you have any concerns, please be sure to ask your therapist during your free consultation.
Which gel is recommended for RF and cavitation treatment?
We advise you apply Ultrasound Gel or Cooling gel (used in hospitals and clinics) for cavitation liposuction treatment. It’s easy to buy such products in your local store. The gel is to help smooth operation and better energy conduction. For RF treatment, you can also use ultrasound gel or cooling gel. Some customer prefer to use oil or creams for RF treatment. Cream is also a great choice. But we don’t recommend oil for RF. Because oil has very high resistance which is not good for RF power transmittance. As those are liquid product, we don’t supply them directly. We advise you purchase from your local market. Please remember to clean those cosmetic products or gels after treatment. Otherwise, it may be harmful for the machine life span.
Do you provide private label/OEM service?
Yes, we have done many successful OEM/ODM service around the world. We can print your logo on the device free of charge. Please contact our customer support for more details.